Luzzi Power SRL
Generating Sets
Opened Gen Sets |
||
---|---|---|
|
|
|
Opened Gen Sets |
Rated power |
Main features |
|||||||||||
50 Hz (1500 rpm) |
60 Hz (1800 rpm) |
||||||||||||
Model |
Depliant (.pdf) |
Prime Power (1) |
Stand-by Power (2) |
Prime Power (1) |
Stand-by Power (2) |
Rounds regulator |
Motor type |
Poles |
Dimensions in mm (L x W x H) |
||||
kVA |
kW |
KVA |
kW |
KVA |
kW |
KVA |
kW |
||||||
GE 8031 i 06 |
20 |
16 |
22 |
17,5 |
24 |
19 |
26 |
21 |
Mechanical |
8031i06 |
4 |
1530 x 700 x 1060 |
|
GE 8031 i 06 |
30 |
24 |
33 |
26 |
35 |
28 |
39 |
31 |
Mechanical |
8031i06 |
4 |
1530 x 700 x 1060 |
|
GE 8041 i 06 |
40 |
32 |
44 |
35 |
47 |
38 |
52 |
42 |
Mechanical |
8041i06 |
4 |
1645 x 700 x 1060 |
|
GE 8061 i 06 |
60 |
48 |
67 |
54 |
70 |
56 |
77 |
62 |
Mechanical |
8061i06 |
4 |
2190 x 700 x 1300 |
|
GE 8061 Si 06 |
80 |
64 |
88 |
70 |
95 |
76 |
105 |
84 |
Electronic |
8061Si06 |
4 |
2190 x 700 x 1300 |
|
GE 8061 Si 07 |
100 |
80 |
115 |
92 |
120 |
96 |
135 |
108 |
Electronic |
8061Si07 |
4 |
2190 x 700 x 1300 |
|
GE 8061 Sri 26 |
125 |
100 |
150 |
120 |
145 |
116 |
160 |
128 |
Electronic |
8061Sri26 |
4 |
2220 x 750 x 1300 |
|
GE 8061 Sri 27 |
150 |
120 |
165 |
132 |
170 |
136 |
185 |
148 |
Electronic |
8061Sri27 |
4 |
2315 x 850 x 1330 |
|
GE NEF 200E |
200 |
160 |
220 |
176 |
225 |
180 |
248 |
198 |
Electronic |
NEF60TE2 |
4 |
2600 x 780 x 1591 |
|
GE CURSOR250 |
250 |
200 |
275 |
220 |
265 |
212 |
292 |
234 |
Electronic |
Cursor250 |
4 |
3100 x 1155 x 2057 |
|
GE 8210 Sri 26 |
300 |
240 |
330 |
264 |
320 |
256 |
350 |
280 |
Electronic |
8210Sri26 |
4 |
3246 x 1350 x 2068 |
|
GE 8210 Sri 27 |
350 |
280 |
385 |
308 |
360 |
288 |
396 |
317 |
Electronic |
8210Sri27 |
4 |
3150 x 1350 x 2128 |
|
GE 8281 Sri 26 |
400 |
320 |
440 |
352 |
450 |
360 |
495 |
396 |
Electronic |
8281Sri26 |
4 |
3262 x 1383 x 2010 |
|
GE 8281 Sri 27 |
450 |
360 |
500 |
400 |
460 |
368 |
510 |
408 |
Electronic |
8281Sri27 |
4 |
3262 x 1415 x 2000 |
(1) Prime Power: Prime Power is the maximum power available for changeable charges for unlimited working hours. The average power usable in a period of 24h must not exceed 80% of declared between the prescribed maintenance intervals at the standard environmental conditions. It is permitted a overload of 10% for one hour every 12 working hours.
(2) Stand-by Power: Stand-by Power is the maximum power available for a period of 500 hours per years with an average charge of 90% of declared Stand-by power. It's not permitted any kind of overload for this use.
It is also possible to use the Gen Set listed above for co-generation applications.